Buy Fog generation systems at Factory Prices


Misting system, misting system is a set of equipment,

Due to the fact that the size of the formed water droplets is negligible, haze is formed - water mist. The finely dispersed water "dust" that makes up the fog evaporates immediately, absorbing heat from the air. At the same time, puddles do not appear on the floor, and moisture does not condense on the surfaces of objects, plants, equipment, on the skin of people and animals.

Artificial fog systems are an effective tool for creating ideal climatic conditions. With the help of fogging systems, cooling, humidification and dust suppression and odor removal of premises or territories are provided.

Such systems can be used both in industry and in everyday life.

It is worth adding that artificial fog is used not only on the street (cafes, restaurants, sports facilities), but also indoors.

This air humidification equipment can be installed in greenhouses, production workshops and points of sale of meat, fruits, vegetables and other perishable products.

The microclimate that such an outdoor cooling system creates has a beneficial effect on human health and well-being, since it allows you to breathe fresh, dust-free air, reduces the risk of bronchopulmonary and cardiovascular diseases.

Decor and special effects
Decor and special effects

Mist cooling system:

  • Reduce temperature;
  • Reduce dust;
  • Raise the humidity level to a comfortable level;
  • Will eliminate or reduce the number of flying insects;
  • Remove unpleasant odors;
  • Create a so-called comfort zone;

Nothing better has yet appeared on the market for cooling outdoor areas.

The fogging system consists of the following elements:

Special pipes, clamps, couplings, fittings are used to create the route and artificial fog nozzles.

The fogging system includes:

Module water treatment, consisting of multiple filters - filter block

High head pressure generating pump module

High pressure pump (70-100 bar)

Low pressure pump (below 10 bar)

Medium pressure pump (10-20 bar)

Low or high pressure nozzles fixed every meter.

Fittings

Nylon tube track

The system can be controlled by built-in control processor, which, based on the specified program, will carry out the water supply process.

The principle of artificial fog cooling system is a phase transition between the liquid and gaseous state of water.

Two main factors must be taken into account for successful cooling.

Air temperature and relative humidity (air saturation water vapor).

The most important factor is the possibility of air exchange, if the room is completely closed without forced ventilation, the fog cooling system will saturate the air with moisture after a while, the water will stop evaporating and the cooling effect will completely disappear.

If the room is sufficiently open or has a forced ventilation system, then the fogging system can be adapted for maximum cooling performance.

Comparison of high and low pressure systems

Low Pressure Average pressure High pressure
Drop size 40-100 µm 5-40 µm 15-25 µm
Pressure Operates directly from a regular city water supply system with a pressure of 1-6 atm. A special pump is required, which creates a pressure in the system from 6-25 bar, as well as special nozzles, fittings and pipes Requires a special pump that creates a pressure in the system from 70 bar, as well as special nozzles, fittings and high pressure pipes
Evaporation temperature In low pressure fogging systems, droplets evaporate effectively at an ambient temperature of 40 C In medium pressure fogging systems, droplets evaporate effectively at an ambient temperature of 32 C, High pressure misting systems can be used at ambient temperatures of 23°C and above

At low pressure, the floor, walls... - will be wet. At high pressure, complete evaporation of wateron contact with the surface.

Why Buy From Us?

17 years on the market
17 years on the market
Work experience since 2004
Any form of payment
Any form of payment
VAT, FOP, VISA, MASTERCARD, GPAY, APPLEPAY, Installment payment, SWIFT, SEPA, PAYPAL, BIZUN
Own import
Own import
Own import, work with the checked suppliers
Cumulative discount
Cumulative discount
Cumulative discount up to 10%
Full cycle
Full cycle
Full cycle of services: design, delivery, installation, service - "turnkey"
Warranty and service
Warranty and service
Full cycle of services: design, delivery, installation, service - "turnkey"
Do it yourself
Do it yourself
Full cycle of services: design, delivery, installation, service - "turnkey"
Information support
Information support
Full cycle of services: design, delivery, installation, service - "turnkey"

Frequently asked Questions

  • low pressure system (2.5-6kgf/cm2)

This type is the cheapest Disadvantage: surrounding objects get wet.

  • medium pressure system (about 15 kgf/cm2)

These systems already require a booster pump. This is a good alternative to high pressure systems. Great for climates with hot and dry air.

  • High pressure system (up to 100 kgf/cm2)

The most preferred type, because produces quality

The timer is the only device for changing the operating mode of the fogging system. The timer, by changing the operating time and pause, allows you to significantly expand the temperature and humidity range of the fog cooling system. For example: in the morning the air temperature is still not too high, but it is already getting hot, the fogging is too dense and excessive humidification is obtained, the fog cooling system without a timer will have to be turned off, but if your "outdoor air conditioner" is equipped with a timer, you can set the operating and pause times and continue to enjoy the established pleasant microclimate. The same can be said about hot, but cloudy days with high humidity.

This is not true, since street air conditioning systems have a very small water intake, even with the smallest water leak, which appears when the nozzle cracks and breaks, the pressure in the system drops with lightning speed, as a result of which the nozzle cannot fly anywhere, especially someone injure.

This is not so, even if hot fine dust is sprayed at low air temperatures, since hot water needs much less energy for a phase transition and the air is quite dry, the water will still evaporate, which will lead to cooling, or at a very low temperature to crystallization i.e. it will snow. But one thing is for sure, the high pressure pump will fail very quickly, since the plunger block is cooled by water passing through it, and if hot water is supplied, the pump will overheat and break.

Control is carried out both manually and automatically using the controller.

In addition to the control unit (a pump is connected to it), the controller includes humidity sensors (hygrometers), compare the readings of air humidity with the required values ​​​​(entered manually ) and control the operation of the pump.

The cyclic timer (time relay) allows you to set the necessary intervals for equipment operation: by hours, days, phases of the day. The user himself regulates the operation in cycles or in the work-pause mode.
In addition, the humidity sensor works on the principle of a thermostat. Fogging equipment can start when a certain lower limit of air humidity is reached and stop working as soon as the desired upper bar is reached. For complex tasks, a combined set of control sensors is used.

• significant decrease in air temperature during the hot season;
• increase in air humidity and creation of a comfortable microclimate;
• increase in aesthetic appeal and exclusivity of the site;
• increase in client flow in public institutions;
• dryness of the ground surface during and after operation of the system (systems with nozzle valves prevent water from flowing through the lower nozzles); br>• reduced irrigation costs;
• increased productivity of the workflow in production.

The answer is simple - low pressure fogging systems (working pressure from 1 to 25 bar.) the basis of spray discs or nozzles with a large outlet, and such technologies do not make it possible to obtain a drop smaller than 25–40 µm. This droplet size effectively evaporates at ambient temperature. environments starting from about 40-43 0С, at lower temperatures such systems work more to moisten surfaces. Therefore, their used mainly in agricultural and landscape design. Fogging high pressure systems (working pressure from 65 to 80 bar) create droplet size from 5 to 15 microns and can be used at temperatures environment from 23 0С.


When salt plugs form on the nozzles, they must be cleaned:
1. Disassemble and place the nozzles in a 5% solution of citric or acetic acid for 24 hours.

2. Blow out with compressed air and assemble the nozzles.

Do not allow the nozzles to dry out.

If the humidifier does not work for a long time, it is recommended to unscrew the nozzles and store them in clean water.

How long your mist system will last depends on the quality of the water. The cleaner and softer the water, the better for the equipment. Water treatment is carried out using special membrane filters, chemicals and electromagnetic softeners. The last method is the most effective and profitable.

The nozzles spray water, and the higher the pressure, the finer the dispersion of the mist.

The spray of water is carried out in the form:

  • fine cloud (most efficient),
  • hollow cone,
  • uniform solid beam (least efficient way).

fine mist, the particles of which can evaporate instantly.

It consists of periodic cleaning of nozzles and filters, in addition, the pump must be checked annually. The inspection includes changing filters and oil. Filters may need to be replaced after 500 hours of operation. In the conditions of the Ukrainian winter, the system is subject to conservation.

Misting can be carried out in two ways: through nozzles or through fans with built-in nozzles.

The first option is a linear system with nozzles that are equipped with anti-drip valves. This prevents the mist from collecting into droplets when the water pressure drops. Its main advantage is ease of installation and customization.

The second option will be indispensable for places where there is no natural air movement; the water cloud is evenly sprayed over the entire cooling object. Fans can be placed on walls, ceilings, or structural frames.